SQL schemes can be validated with ConnexOne database application control
6.1.1 Overview Ping
You can use the ping function to check whether a device with a specified address is reachable, and to examine network connectivity. A successful execution of the ping command involves the following steps:
The ping command can be applied to the destination’s host name or IP address. If the destination’s host name is unknown, the prompt information is displayed.
If the source device does not receive an ICMP echo reply within the timeout time, it displays the prompt information and the statistics during the ping operation. If the source device receives an ICMP echo reply within the timeout time, it displays the number of bytes of the echo reply, the message sequence number, Time to Live (TTL), the response time, and the statistics during the ping operation. Statistics during the ping operation include number of packets sent, number of echo reply messages received, percentage of messages not received, and the minimum, average, and maximum response time.
Traceroute
By using the traceroute command, you can display the Layer 3 devices involved in delivering a packet from source to destination. This function is useful for identification of failed node(s) in the event of network failure.
The traceroute command involves the following steps in its execution:
This process continues until the ultimate destination device is reached. In this way, the source device can trace the addresses of all the Layer 3 devices involved to get to the destination device.
The traceroute command can be applied to the destination’s host name or IP address. If the destination’s host name is unknown, the prompt information is displayed 6.1.2 Diagnostic tool operations ping operation
6-2.


Traceroute operation

Optical fiber is commonly used for long distance data transmission. However, when link issues occur, it is very costly to troubleshoot fiber cables and fiber transceivers at remote sites. To solve this problem, Moxa industrial Ethernet switches provide digital diagnostics and monitoring (DDM) functions on SFP optical fiber links and allow users to measure optical parameters and its performance from a central site. This function can greatly facilitate the troubleshooting process for optical fiber links and reduce costs for onsite debugging. 6.2.1 Displaying Optical Transceiver Information
Select Diagnosis > Optical Transceiver Information from the navigation area. The system automatically displays the optical transceiver information, as shown in Figure 6-4. Table 6-1 describes the optical transceiver information items.

Table 6-1: optical transceiver information items
| Item | Description |
|---|---|
| Name | Switch port number that the SFP is plugged into. |
| State | The state of the fiber interface, up/down. |
| Transceiver State | The absent of the transceiver. |
| Temperature(degree) | SFP casing temperature |
| Voltage(V) | Voltage supply to the transceiver. |
| Current(mA) | Current consumed by transceiver. |
| Rx Power(dBm) | The amount of light being received from the fiber optic cable |
| TX Power(dBm) | The amount of light being transmitted into the fiber optic cable |
| Detail | Click to show the detail information of the transceiver. |
6.2.2 Displaying detail information
Click DETAIL of the interface to enter the page of transceiver detail information. as shown in Figure 6-5.

Each functional module has its own running information, and generally, you need to view the output information for each module one by one. To receive as much information as possible in one operation during daily maintenance or when system failure occurs, the diagnostic information module allows you to save the running statistics of multiple functional modules to a file, and then you can locate problems faster by checking this file.

6.4.1 Overview
The networking devices rely on a temporary back-up power supply on a capacitor, that allows for a graceful shutdown and the generation of the dying-gasp message. This temporary power supply is designed to last from 10 to 20 milliseconds to perform these tasks.
According to the definition in 802.3ah, when a device power failure event occurs, the device sends an OAM event message to its connected device. Since OAM is a point-to-point protocol, the power failure event message will not be sent to the next device that supports OAM. Continue to forward again. The device that receives a power failure event will output a power failure LOG prompt message.
In addition to the OAM alarm information, the power-off device will also send a trap message to the smmp server.
Node information Data Mib files DOT3-OAM-MIB.mib oid 1, 3, 6, 1, 2, 1, 158, 1, 6, 1, 4 value dyingGaspEvent(257) 6.4.2 Configuring Dying Gasp

Only electrical ports support this command Performing this operation will cause the already Up port to automatically go Down and Up again.
When the line length is less than 6 meters, there is a deviation between the test results and the actual value.
Only electrical ports support this command Performing this operation will cause the already Up port to automatically go Down and Up again.
When the line length is less than 6 meters, there is a deviation between the test results and the actual value.
Cable detection means that users can detect the current status of the cable connected to the Ethernet interface on the device, and the system will return the detection results within 5 seconds. The detection content includes whether there is a short circuit or open circuit in the cable and the length of the faulty cable.
Step 1: Select Diagnosis > Cable Detect in the navigation bar to enter the cable detection page, as shown in Figure 6-8.
Step 2: Select the interface to be tested, click the Detect button to start the incoming line test, and the system will return the test results within 5 seconds.
Step 3: As shown in Figure 6-9, view the detection results on the pop-up page.


Pair X length: unit meter, cable length, in case of fault, the length from the interface to the fault location
Pair X status:
OK (normal): Indicates that the line pair (PAIR) is terminated normally Open: Indicates that the line pair is open Short: Indicates a short circuit on the pair Unknown: Other unknown causes of failure Pair X length: unit meter, cable length, in case of fault, the length from the interface to the fault location
Pair X status:
OK (normal): Indicates that the line pair (PAIR) is terminated normally Open: Indicates that the line pair is open Short: Indicates a short circuit on the pair Unknown: Other unknown causes of failure